Cintec Technology Announces Innovative New Dissipative Anchor

Words: Bronzella Cleveland

New anchor ideal for protecting historic buildings in areas of high seismic activity

Cintec International, a leader in the field of structural masonry retrofit strengthening, repair, and preservation, has developed a new type of dissipative wall anchor. The new anchor solves the issues of how to protect heritage buildings in some of the most earthquake-prone parts of the world. This new product is designed for use with Cintec’s proven wall anchor system.

“We believe that this anchor is a major breakthrough in further protecting the world’s iconic buildings, especially in areas of high seismic activity,” said Peter James, managing director of Cintec International. “This anchor has been four years in development within the NIKER program. It has undergone extensive testing at Bath University, and in Italy.”

The standard Cintec anchor system consists of a stainless steel anchor body encapsulated in a fabric sock. Diamond holes are drilled into the building and each anchor is placed in a hole. A specialized grout in pumped to the far end of the anchor, filling from back to front until the entire sock is inflated like a balloon. After the anchor has been inflated, the walls have been securely strengthened without affecting the outside appearance of the building.

For buildings subject to regular earthquake activity, there is a possibility of pull-out damage at the anchorage head. The new anchor solves this problem by allowing for small amounts of movement through a sliding mechanism.

The Cintec dissipative anchor consists of a set of stainless steel plates to which four bolts apply pressure, creating friction to an adjustable degree. There are built-in stops to restrict the sliding motion, and connectors that link to Cintec’s standard anchor rods. The anchor allows a controlled and repairable drift for the walls, managing the amount of seismic energy fed into the structure and therefore minimizing damage to the building.

The development of this anchor resulted from Cintec’s involvement with the European NIKER project. In 2011, Cintec was chosen as the only British commercial company to actively participate in this project, the aim of which was to protect the artistic value of cultural heritage sites from earthquake-induced damage. Cintec has been working in collaboration with the University of Bath to create and test the dissipative anchor since then, and has now patented the finished product.

Cintec anchors have been used to strengthen and restore historically significant structures around the globe, including Egypt’s pyramids, Windsor Castle, and even the White House.

Restoring Structural Integrity: Reinforcement in Masonry Buildings
August 2026

Masonry, as most of us in the trade know and appreciate, remains one of the most durable and time-tested structural systems in the built environment. Structures built throughout Europe and other parts of the world demonstrate that a masonry building is mo

Designing High-Performance Masonry Envelopes: Selecting the Right Air Barrier System
August 2026

Beyond the Block: Aesthetic Innovations in CMU Construction
August 2026

Concrete masonry units (CMUs) have long been a mainstay of construction. They are well known as a “tried and true” material with a long history of high-strength structural performance, affordability, ease of assembly, and a long lifecycle. CMU constructio

The Most Overlooked Profit Center on Your Job Site
August 2026

The real cost of equipment ownership isn't what you pay on day one. It's what happens over the years that follow. The purchase price of a new mortar mixer, grout pump, material handling system, or masonry saw is only part of the investment. What happens