Flashing: Masonry Flashing

Words: Dan Kamys
Holding flashing back from the wall face can result in entry points for moisture to penetrate the wall.
Holding flashing back from the wall face can result in entry points for moisture to penetrate the wall.

Mason contractors are usually directed to install flashing with their masonry product. Flashing acts as a barrier which redirects moisture away from building interiors and back toward the exterior of the wall. Common flashing materials include synthetic membranes (peel and stick) and metals, such as copper and stainless steel. The material that is used will directly affect the expected lifespan of the flashing, especially where flashings are exposed to sunlight or weathering.

Flashing needs to be accompanied by a weep mechanism to allow moisture to exit the wall, often in the form of weep holes or head joint vents at horizontal terminations. The weeps should be placed directly above the flashing and extend all the way to masonry drainage plane. In order for moisture to reach and exit the weeps, both the weeps themselves and the drainage cavity adjacent to the weeps should be kept clear of mortar clogging. Installation of vents at the top of a drainage cavity aids air flow behind the masonry, decreasing drying time and reducing the risk of efflorescence.

Drip edges force moisture at flashings away from the face of the wall and reduce the amount of moisture that can bypass or be re-absorbed beneath a flashing. Flashing materials, such as asphalt can soften and melt onto the face of masonry with UV or high heat exposure. These flashing types must be cut or held back the wall face, and a drip edge can be used to direct moisture away from the wall face. The drip edge must be made of a material that is not sensitive to UV exposure and won’t corrode.

Flashing is required for veneer in cavity wall systems, but it is also required for structural masonry. The building code requires that flashing be designed and detailed, so if project drawings don’t show where flashing is supposed to be installed, be sure to check with the designer (in writing). Some locations where flashing is likely to be needed are:

  • Base of wall (usually at each story)
  • Lintels above openings
  • Under sills, caps, and rowlocks
  • Beam pockets
  • Penetrations (plumbing, electrical, ventilation)

Workmanship and detailing are important to the success of a masonry flashing system. Seams between separate flashing pieces need to be lapped and properly sealed using products approved by the flashing manufacturer. End dams are often required at flashing terminations such as at the edges of lintels and inside corners. The use of manufactured inside and outside corner flashings can simplify flashing installation and reduce the number of seams and potential leak locations in a masonry flashing system.

Use of end dams at the edges of lintels is recommended.  Manufactured corner pieces are available for this purpose.
Use of end dams at the edges of lintels is recommended. Manufactured corner pieces are available for this purpose.

If there are questions about the performance of a masonry drainage and flashing system, it can be evaluated using ASTM C1715, “Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems.” The test involves introducing a controlled flow of water directly into the cavity, and directly observing the moisture path as the water interacts with flashing and weeps.

Masonry cavity drainage testing in progress.
Masonry cavity drainage testing in progress.

For free information and industry recommended masonry flashing details, see the following resources:

Brick: Brick Industry Association (BIA) Technical Notes on Brick Construction No. 7: Water Penetration Resistance - Design and Detailing.

CMU: National Concrete Masonry Association (NCMA) TEK 19-5A: Flashing Details for Concrete Masonry Walls.

Adhered Manufactured Stone Veneer: Masonry Veneer Manufacturer’s Association (MVMA) Installation Guide and Detailing Options for Compliance with ASTM C1780.

2025 SkillsUSA National Competition Recap
August 2025

The 2025 SkillsUSA National Competition served as a critical platform for evaluating the future of the masonry industry. The event provided a clear look at the talent pipeline, industry-wide collaboration, and technological advancements poised to shape th

Empower Your Team to Help Prevent Cyberattacks
August 2025

Human error contributes to 82% of data breaches, making your employees a crucial line of defense against cyber threats.1 A single mistake could expose your business to a data breach. This could lead to data loss, downtime, and a negative impact on your bo

The True Costs of Traditional Wood Bucks: Beyond the Lumber Bill
August 2025

Wood bucks have been holding up CMU block on masonry jobs for decades now, albeit precariously. This infamous lumber has been sawed, screwed, braced, and cursed more often than anyone would want to count. For something meant to be temporary, they have cle

Remembering Kevin O'Shea
August 2025

It is with profound sadness that we announce the passing of Kevin O'Shea, a treasured figure in the industry, who passed on August 13th, at the age of 64. Kevin was not only the Safety Director at Hydro Mobile but also the Chair of the Safety Committee fo